Watch Dog Series D463 NEMA 4X Duplex Control
FEATURES:
D463
  • Flashing Red Alarm Light
  • 2 - Amber Run Light
  • High Decibel Audible (optional)
  • NEMA 4X Fiberglass Enclosure
  • Stainless Piano Hinged Door
  • Stainless Door Latches w/ Padlock Hasp
  • External Mounting Feet
  • Automatic Alternating Relay/Override Circuit
  • 2 - Adjustable Overload Relay
  • 2 - 3 Pole, Non-Reversing Contactors
  • 2 - "Hand/Off/Auto" Heavy Duty Toggles
  • Alarm "On/Off/Test" Heavy Duty Toggle
  • Field Wiring Terminal Strips
  • 2 - Motor Circuit Breakers
  • Control Circuit Transformer - Primary Fusing & Breaker
  • Individual 3 Amp Control/Alarm Circuit Fuses
  • UL 508A Listing (optional)
  • One Year Limited Warranty
Click Picture for Larger Image
APPLICATIONS INCLUDE:
Starting & Stopping Pump for:
Sump & Sewage Basins
Septic Tanks & Aeration Systems
Cisterns & Atmospheric Storage Tanks
Chemical Solution Tanks
And Many More...
AVAILABLE OPTIONS:
Piezo Buzzer
Alarm Bell
Vibrating Horn
(Automatic reset silence circuit included with all audibles)
UL 508A Listing
No Motor Heat Sensor
or Seal Fail Probes
Specifications
Model
Location Use
Max
Full Load Amps
Enclosure Type
Enclosure Material
Input
Power
VAC -Ph
Audible Included
Alarm Fuse
Control Fuse

Approx.
Ship
Weight

D463
Outdoor
18
NEMA 4X
Fiberglass
460-3
---
3 Amp
3 Amp
38 lbs
D463P
Outdoor
18
NEMA 4X
Fiberglass
460-3
Piezo
3 Amp
3 Amp
38 lbs
D463B
Outdoor
18
NEMA 4X
Fiberglass
460-3
Bell
3 Amp
3 Amp
39 lbs
D463H
Outdoor
18
NEMA 4X
Fiberglass
460-3
Horn
3 Amp
3 Amp
39 lbs
** Add Suffix For FLA Requirement (See table below)
*Add Suffix - FB to Model # If Ordering Float Switch and Float Switch Mounting Bracket Option
Float Kit Includes (4) MPF-0-10 Float Switches & (1) FSB-SS4 Float Switch Mounting Bracket
** FLA Rating Table
FLA
Suffix
FLA
Suffix
.063-1.0
-05
5.5-8
-12
1.0-1.7
-06
7-10
-14
1.6-2.5
-07
9-13
-16
2.5-4
-08
12-18
-21
4-6
-10
   
**This "Watchdog" Series panel is for small effluent type pumps only. No provisions for motor heat sensors or seal probes are provided. When ordering any of the above panels, match the full-load-amperes (FLA), of the pump(s) you are using to the chart on the right and add the proper suffix to the model number. EXAMPLE: You need a simplex control panel with alarm light and bell - your pump is 460 V with FLA rating of 5 - Order Model #D463B-10 for panel only or Model #D463B-10-FB if you want the float kit included